Fifth generation endodontic treatment technology

Root canal treatment is carried out during endodontic treatment. This manipulation is performed to prevent the spread of the infectious process to the surrounding periodontal tissue. At the World of Dentistry clinic, specialists use modern methods of root canal treatment, which make it possible to save even a severely damaged unit.

Several decades ago, dental canal treatment was accompanied by quite severe discomfort. Today this procedure is performed under local anesthesia using high-quality effective drugs. Root canal therapy is required when there is inflammation or infection to save the unit. Our specialists resort to tooth extraction in the most extreme cases. After cleaning the dental canals, the unit will last for another year.

Stages of root canal treatment

  1. Providing access to canal mouths:
  • Formation of cavities in the tooth of the correct size, shape and in a certain quantity.
  • Cleaning the tooth from tissues affected by caries and removing old fillings. Endobors are used for this purpose.

Endoburs are cylindrical or cone-shaped heads made of hard alloys or diamond chips.

  1. Expansion of the mouths of the dental canals. This stage ensures the convenience of the procedure and involves the formation of a funnel-shaped entrance to the root canal.
  2. Extraction of the contents of dental canals. The pulp is completely removed using special pulp extractors:
  • The pulp extractor is slowly placed into the canal until the instrument begins to come into contact with its walls.
  • After this, the pulp extractor is rotated 360 degrees. In this way, the nerve bundle is captured and removed. Normally, the pulp should be completely removed.
  • The channels are treated with an antiseptic solution. Evaluation criteria: the pulp from the canal is completely removed, there is a free lumen of the canal.
  1. Determination of the working length of the root canal. For this purpose, root needles or special endodontic rulers are used. It is necessary to measure the working length of the canal in order not to damage the periapical tissue. The working length is the distance from the highest point of the dental crown to the beginning of the narrowing of the canal. This indicator can be determined in three ways:
  • Estimated length of tooth and root.
  • Using radiography.
  • Electrometric method.

Special tables containing the minimum, average and maximum dimensions of tooth length help determine the length of the dental canal.

  1. Mechanical treatment of root canals. It consists of processing them with special tools and subsequent expansion to the required size.
  2. Canal filling. Gutta-percha is usually used for this.

Indications for use

Coronary-apical techniques are recommended for use in the following cases:

  • Extensive infection of the internal structure, increasing the risk of deformed pulp elements entering the apical part;
  • The need to remove filling material previously installed inside the root canal;
  • Availability of recommendations for the use of automated nickel-titanium or GT files.

Types of technologies used

The protocols recommended for endodontic treatment include the following technologies.

Step Down

The Step Down technique is focused on the formation of a cone-shaped working channel, which provides ease of interaction with the apical structure and filling of gaps. Involves the use of files of several sizes, and helps to expand and clean the cavity, as well as create a smooth surface that improves the quality of re-closure with a filling. After finding the working length, the apical zone is cleaned using the Stepback technique, while the lower area of ​​the canal takes on a conical shape, with an apical stop formed in the apical part. The use of nickel-titanium profiles promotes the formation of an optimal structure and eliminates the development of complications due to the instant removal of individual particles.

Crown Down

Crown Down is a technique in which advancement is carried out from the crown to the gum, and the removal of root contents and parietal dentin is carried out in parts. It is recommended if it is necessary to create a funnel-shaped mouth, which is necessary for difficult passage of streamers, and also allows you to stop the exacerbation of periodontitis. The complexity of the technology necessitates the use of automated equipment, but it is important to prevent excessive expansion, which could affect the strength of the crown structure and dental tissue. To control the immersion depth of equipment, radiographic imaging is recommended.

Using instruments with an enlarged cross-section, the dentist gives the cone the necessary structure, creating a funnel and regularly using an antiseptic to prevent infection. GatesGlidden bur models are used for expansion and deepening, thanks to which a comfortable platform is created that eliminates the presence of damaged areas and preserves the tooth structure. The technique eliminates the entry of affected elements beyond the apical foramen, and preserves the natural shape of the canal without affecting healthy tissue.

Current processing techniques contribute to the preservation of dentition elements. A timely visit to the dental clinic allows you to monitor the condition of the oral cavity and take preventive measures in a timely manner, preventing negative developments and infection of the root canals.

Mechanical treatment of root canals

The main task of mechanical treatment of dental canals is their expansion for the purpose of high-quality filling. If mechanical treatment is not carried out, the channel will be heterogeneous, having narrowings and expansions. This factor will become an obstacle to completely filling the canal with filling material.

Mechanical treatment of dental canals can be carried out in two ways:

  1. Using hand tools. The method involves placing medical devices into the root canal and gently rotating them.
  2. Using an endodontic handpiece. Special profile files made of nickel-titanium are placed in the tips. Under the influence of the tip, the pro-file rotates in the channel, and its sharp edges remove chips from the walls of the channel, making it wider. The advantage of pro files is the so-called shape memory. Thanks to this feature, the instruments do not break even in very curved canals. This eliminates the risk of serious complications associated with a piece of dental instrument remaining in the canal.

Benefits of using an endodontic handpiece

  • Compared to the use of hand instruments, the endodontic handpiece provides better treatment of the canals. After machine processing, the canal walls become very smooth. This allows for easy insertion of gutta-percha filling pins.
  • Treatment with an endodontic handpiece takes significantly less time compared to manual treatment.
  • The technique is safe. Typically, the handpieces are equipped with a micromotor that controls the rotation of the pro-file in the dental canal. If the permissible load is exceeded, the micromotor stops the rotation of the pro-file. Thus, there is no risk of tool breakage, which cannot be guaranteed with manual processing. Not every doctor can feel the extreme resistance at which the instrument may break.

Our clinic uses machine processing using “smart” instruments. The processing is carried out by top-level specialists. Therefore, we can guarantee the safety of the procedure.

Fifth generation endodontic treatment technology

Since the advent of modern endodontics, many concepts, strategies and techniques for root canal treatment have been developed. For decades, new files for passing and forming channels have appeared on the market. But, despite the variety of instrument designs and many techniques, the success of endodontic treatment was and remains just a probabilistic event.


Endodontic treatment has evolved from the use of a range of stainless steel hand files and rotary instruments such as Gates Glidden to modern Ni-Ti canal shaping files. Despite the development of modern processing methods, the mechanical aspects of the canal work were excellently described 40 years ago by Dr. Herbert Schilder. With careful execution of mechanical principles, the biological feasibility of treatment, 3D disinfection and successful filling of the root canal system are observed (Photo 1a - 1d).

Photo 1a. CT image of a maxillary central incisor showing a root canal system with multiple branches

Photo 1b. X-ray showing failed endodontic treatment

Photo 1c. Retreated tooth with 3D cleaning of the canal lumen and proper filling

Photo 1d. Follow-up photo showing bone restoration

The purpose of this article is to trace how each generation of Ni-Ti files has led to the development of advanced canal preparation techniques. More importantly, the authors will attempt to identify and describe clinical techniques that combine the most proven concepts of the past with the latest innovative developments.

Nickel-Titanium when working in a channel

In 1988, Walia introduced nitinol, a Ni-Ti alloy, for canal processing because it is 2-3 times more flexible than steel files of the same size. The main difference between Ni-Ti channels was that they were able to machine the most curved channels through repeated rotating movements. In the mid-90s, the first affordable Ni-Ti files hit the market. Next, the classification of each generation of files will be presented. In general, they can be characterized as tools that perform passive rather than active cutting actions.

First generation

To appreciate the entire evolution of Ni-Ti tools, it is useful to know that the first generation of Ni-Ti files had passive radial cutting and a fixed 4% taper and 6% active blades (Photo 2). This generation required the use of a whole set of files for a complete canal preparation. Already in the mid-90s, GT files (Dentsply Tulsa Dental Specialties) became available, providing fixed tapers of 6%, 8%, 10% and 12%. The most distinctive feature of the first generation of Ni-Ti files was passive radial cutting, which forced the file to remain centered when working in curved canals.

Photo 2: Two electron microscope photographs showing a cross-section and side view of a file with radial slicing and passive edges.

Second generation

The second generation of Ni-Ti files appeared on the market in 2001. The main distinguishing feature of this generation of instruments is the presence of active cutting edges and the need for fewer instruments for complete canal preparation (Photo 3). To level out the taper block and screw effect in passive and active Ni-Ti instruments, EndoSequence (Brasseler USA) and BioRaCe (FKG Dentaire) offered a line of files with alternative contact points. Although this feature was added to eliminate the taper block, this line still had taper on the active parts. The industry breakthrough came with the introduction of ProTaper (DENTSPLY Tulsa Dental Specialties), which created different levels of taper on a single file. This revolutionary idea allowed files of different tapers to be applied to a specific area of ​​the root canal and provide safe and deep treatment (Photo 4).

Photo 3: Two electron microscope photographs showing a cross-section and side view of an active file with sharp cutting edges.

Photo 4. ProTaper (DRNTSPLY Tulsa Dental Specialties) cutting surfaces are predominantly located in the upper and middle thirds of the instrument, while the finishing file has a cutting surface in the apical third.

During this period, manufacturers placed a major emphasis on methods that increased the file's resistance to breakage. Some manufacturers have used electropolishing to remove any unevenness from the file surface caused by the normal sanding process. However, this electropolishing has been clinically and scientifically proven to dull the sharp edges of the tool. For this reason, for routine processing, the doctor has to apply excessive pressure on the file. High pressure on the tool leads to jamming of cone files, a screw effect and excessive bending during operation. To compensate for electropolishing, more cross-section options began to appear, and increased rotation speeds began to be recommended, which is also somewhat dangerous.

Third generation

Improvements in Ni-Ti metallurgy became a major development that can be identified with the advent of the third generation of endodontic files. In 2007, manufacturers began to place greater emphasis on heating and cooling techniques to reduce cyclic fatigue and improve safety when working in more curved channels. The third generation of Ni-Ti tools is characterized by less cyclic fatigue and fewer breakdowns. Examples of brands working with this technology: Twisted File (AxislSybronEndo); HyFlex (Coltene), GT, Vortex, WaveOne (DENTSPLY Tulsa Dental Specialties).

Fourth generation

Another advance in canal preparation technology is the advent of the technique of repeated up-down and reciprocating movements. This method was first proposed by the French dentist Blanc in the late 1950s. Currently, the M4 (AxislSybronEndo), Endo-Express (Essential Dental Systems), and Endo-Eze (ultradent Products) are examples of systems where the number of clockwise movements is the same as the counterclockwise movements. Compared to full rotation, reciprocal files require more pressure on the instrument, do not cut dentin as effectively and are somewhat less efficient at removing sawdust from the canal lumen.

Innovations in reciprocal technologies have led to the emergence of the fourth generation of files. This generation has finally realized the dream of using one single file for channel processing. ReDent-Nova (Henry Schein) self-adapting file (SAF). This file is shaped like a compressible hollow tube, which can provide uniform pressure on the canal walls regardless of the cross-sectional shape of the canal. The SAF is installed in a tip that provides short 0.4 mm vertical oscillation and vibration. Irrigation is also constantly carried out through the file cavity. Another single file technique is One Shape (Micro-Mega), which will be mentioned in the fifth generation.

The most popular single file technique is WaveOne and RECIPROC (VDW). WaveOne is a combination of the best qualities of the second and third generation files, coupled with a reciprocal motor that drives the instrument. After three cycles of clockwise and counterclockwise movements, the file rotates 3600 or makes one circle (Photo 5). Such movements allow you to work more efficiently, remove dentin and move it outside the canal.

Photo 5. WaveOne (DENTSPLY Tulsa Dental Specialties) reciprocal file, which has an unequal number of counterclockwise and clockwise angles, allowing more efficient work in the canal and removing dentin filings beyond its boundaries

Fifth generation

The fifth generation of endodontic files are designed in such a way that the center of gravity and the center of rotation are shifted (Photo 6). When rotated, files with a displaced center of gravity produce mechanical movement that extends along the active part of the tool. Just like ProTaper progressive tapered files, these offset file designs minimize binding between the file and the dentin. In addition, this design facilitates removal of dentinal debris from the canal and increases the flexibility of the active portion of the ProTaper Next (PTN) file (DENTSPLY Tulsa Dental Specialties). The benefits of the offset design will also be discussed later in this article.

Figure 6: Cross-section of a ProTaper Next (PTN) file (DENTSPLY Tulsa Dental Specialties). Note the offset shape, which reduces jamming and increases tool flexibility

Examples of commercial brands that offer variations of the technology described are Reco-S (Medidenta), One Shape, and the ProTaper Next (PTN) file system. Today, the safest, most effective and simplest tool, combining the advantages of past and modern developments, can be considered the PTN file system.

Protaper Next

There are 5 types of PTN files of various lengths on the market, labeled X1, X2, X3, X4, X5 (photo 7). The file handles have yellow, red, blue, double black and double yellow marking rings corresponding to sizes 17/04, 25/06, 30/07, 40/06 and 50/06. PTN X1 and X2 have both rising and falling active tapers, while PTN X3, PTN X4 and X5 have fixed tapers D1 to D3.

Photo 7. There are 5 PTN files in the image. Most canals in back teeth can be treated with 2-3 instruments.

PTN files combine 3 important features: progressive taper on one tool, M-wire technology and the main advantage of the fifth generation - a shifted center of gravity. For example, PTN X1 and X2 have both rising and falling tapers, while X3, X4 and X5 are designed with a fixed taper from D1 to D3, and in the D4-D16 range the X1 file has an offset center of rotation. Starting from 4%, the X1 file increases the taper from D1 to D11, and from D12 to D16 the taper decreases to increase flexibility and preserve radicular dentin during processing.

PTN files are used with a rotation of 300 rpm and a slope of 2-5.2 ncm, depending on the technique used. However, the authors prefer a slope of 5.2, since they consider it as safe as possible for vertical operation of the canal and removal of sawdust from the lumen. In the PTN technique, all files are used in the same sequence according to the ISO color markings, regardless of the length, diameter and curvature of the canal.

Root canal technology

The PTN technique is very safe, effective and simple when attention is focused on proper root canal access and gliding technique. As with all other techniques, PTN requires strictly direct access to each orifice. The main focus is on passing, widening and smoothing the inner walls of the root canal. To access the canal, the ProTaper system offers an additional file called SX. The movements of this file are carried out like a brush, and it is able to expand the mouth, remove dentin triangles and, if necessary, give a clearer shape to the canal.

Perhaps the greatest difficulty in endodontic treatment is to find the canal, follow its course and bring it intact to the end of treatment. Processing and saving channels when working with small manual files requires strategy, high skill, patience and desire. Small hand files are typically designed to locate, enlarge and clean out the walls of root canals. Once the canal is prepared manually, a mechanical file can be used to widen the canal and perform other manipulations. To be precise, a canal can be considered ready and processed when it is clean and has strong, smooth walls.

After determining the working length, file No. 10 is inserted into the canal lumen and it is determined whether unimpeded movements with the instrument are possible to the top of the canal. In short, wide and straight channels this operation is much easier. After successful completion of file #10, either file #15 or a designated mechanical file such as PathFiles (DENTSPLY Tulsa Dental Specialties) is used. This file is intended to confirm that there is sufficient space to begin processing with the PTN X1.

In many other cases, endodontic treatment involves teeth with longer, narrower, and curved canals (Figure 8a). In such a situation, file #10 very often cannot travel the entire length of the canal. In general, there is no need to use hand files No. 8 and No. 6; it is enough to simply work carefully with file No. 10 on each canal segment until the tool begins to fit freely. PTN files can be used to form any section of the channel prepared for passage. Regardless of the technique and all manipulations, the main goal remains to prepare the canal along its entire length, establish the working length and locate the apex (Photo 8b). The canal is considered prepared when file No. 10 passes freely through the canal, including in its apical third.

Figure 8a: This x-ray shows an endodontically involved posterior abutment tooth for a bridge. Pay attention to the position of the prosthesis in relation to the roots.

Figure 8b: Working image shows the exposed crown, isolation and inserted #10 files demonstrating canal curvature.

After working with the canal, the cavity from which access was made is washed with a 6% sodium hypochlorite solution. Channel formation can begin with PTN X1. It should be emphasized that PTN files are never used with a pumping type of movement; on the contrary, with PTN, return movements of the brush type are required. Using this technique, the doctor easily moves along the walls of the canal and forms the required working length. The X1 file is passively inserted into the canal through a pre-expanded orifice. Until a stop is felt, they immediately begin brush-type movements, sweeping towards the inlet (Photo 8c). Such movements help to gain additional space on the side and move the file a few millimeters deeper. Brush movements increase contact with dentin, which is especially important in canals with an asymmetrical cross-section and convex parts.

Photo 8c: PTN X1 file shown in action.

Work with PTN X1 continues. After every few millimeters, the file is removed from the canal for inspection and cleaning of sawdust. Before re-introducing PTN1, it is necessary to irrigate and clean the canal from sawdust. Then the channel is again passed through file No. 10 to remove remaining particles and washed abundantly with the solution. Subsequently, one or more cycles with PTN X1 cover the entire working length. To improve quality, it is necessary to constantly flush the canal and inspect the instrument.

After the first stage, they begin to work with PTN X2. Before the instrument rests in the canal, cleaning movements are carried out along the walls, which allows the file to advance to its maximum depth. X2 follows the path created by PTN X1, forming the canal walls and extending to working length. If the tool does not go deep, it should be removed, cleaned of chips and checked for integrity. The canal should then be rinsed and the instrument reinserted. Depending on the initial data of the canal, its shape, curvature and length, one or more cycles of file insertion are required before passing along the entire working length (Photo 9a).

Figure 9a: The mesial buccal canal contains PTNX2.

After reaching the apex, PTN X2 is removed from the canal. A sign of completion of canal treatment is the filling of the instrument teeth in the apical part with dentinal filings. An alternative is to measure the hole using a 25/02 Ni-Ti hand file. If No. 25 runs tightly along the entire length, then the formation of the channel is completed. When 25/02 enters too freely, the hole is larger than 0.25 mm. In this case, use file 30/02, which, if tightly fitted, also indicates the completion of canal processing. If file 30/02 is short in length, then PTN X3 is used according to the method described above.

The main number of channels is optimally formed when using either PTN X2 or X3 (Photo 9b). PTN X4 and X5 are usually used for large diameter channels. When the apical foramen is larger than PTN 50/06 X5, other techniques are used to complete the treatment of these larger, usually less curved canals. Each canal must be carefully navigated, 3D cleaned and filled for a successful result (Photo 9c).

Figure 9b: In the distal canal of PTN X3.

Photo 9c: X-ray after treatment. A bridge was placed. The anatomical shape of the canals is not disturbed.

Discussion

From a clinical point of view, the PTN system is the most advanced and combines all the advantages of previous generations of instruments and the latest developments. A little discussion will help to understand how the design of a tool affects its performance.

The most successful generation of tools are those that use progressive taper on a single file. The patented ProTaper Universal Ni-Ti system combines ascending and descending taper on one tool. This design reduces the likelihood of tool jamming in the canal, the screw effect, and works more efficiently. Compared to files with a fixed taper, the presented instruments are highly flexible, limit dentin removal and preserve tissue in the coronal 2/3 of the canal. The resulting design allows ProTaper to become the #1 selling file worldwide, the choice of endodontists and a technique taught in all dental institutes.

Another advantage is the material used. Although Ni-Ti files show 2-3 times more flexibility than stainless steel files, the metallurgical industry has realized some more benefits when heating. Research has focused on heating and cooling of traditional Ni-Ti alloys, both before and after processing. Heating allows you to create an optimal phase between the components of the alloy. Research has shown that M-wire, a metallurgically advanced version of Ni-Ti, reduces cyclic fatigue by 400% compared to a file of the same diameter, section and taper.

This development is also a strategic enhancement to the clinical safety of the PTN file system.

The third design feature is the shifted center of gravity. There are 3 main advantages associated with such a device:

  1. When rotated, files with a displaced center of gravity produce mechanical movement that extends along the active part of the tool. The rocking effect minimizes the adhesion of the file to the dentin, compared to files with a fixed taper and a non-displaced center of rotation (Photo 10). Reduced grip reduces the likelihood of tool jamming, screw effect and bending.
  2. The off-center file design adds additional cross-sectional space, allowing for better removal and removal of dentinal debris from the canal (Figure 10). Breakage of many instruments often occurs precisely because the teeth of the instrument are filled with sawdust from hard tissues. This design also minimizes the likelihood of obstruction of the canal by sawdust and disruption of its anatomy (Photo 6).
  3. A file with an offset center of gravity produces a wave that resembles a sine wave (Photo 11). As a result, PTN can perform more action than other files with similar input data (Photo 6). There is a clinical benefit to using a smaller, more flexible PTN file in areas that previously required larger, more rigid instruments (Figure 10).

Photo 10: PTN files have a progressive taper and offset design. These features reduce jamming, maximize dentinal debris removal, and increase flexibility. For comparison, the figure below shows a file with a fixed taper, center of gravity and axis of rotation.

Photo 11. Similar to a sine wave, PTNs form a wave when moving and provide a “swinging” effect throughout the working part.

Conclusion

Each new generation of endodontic files offers something useful, innovative, thereby trying to surpass the previous generation. PTN, now in its fifth generation, has become a unique example of combining the success of previous experience with new technological improvements. The created system is designed to simplify the process of endodontic canal treatment by reducing the number of instruments required for use.

Clinically, PTN fulfills the three pillars of canal treatment: safety, effectiveness and simplicity. From a scientific point of view, continued research is needed to confirm the effectiveness and identify all the important points when working with these tools.

Authors: Clifford J. Ruddle, DDS, MSD; Pierre Machtou, DDS, MS, PhD; and John D. West, D.D.S.

Treatment of canals using chemicals

Chemical treatment is used when mechanical cleaning is not possible. Usually the procedure is performed using chemicals when the canals are too narrow or completely impassable. After chemical treatment, mechanical treatment can be carried out.

Previously, nitric and hydrochloric acids were used for the procedure. But later they abandoned these substances, since they burned the surrounding tooth tissues when they got on them. Today, calcium salts and chelating agents are used. They can be in liquid or gel form. Solutions of calcium salts penetrate well into narrow channels. The advantage of these substances is their antiseptic property. In addition, they contain EDTA, which provides good glide for instruments. Chemical treatment is carried out in several stages:

  • The cavity in the tooth is thoroughly dried.
  • A solution is placed in it and injected.
  • After penetration of the chemical, the channel is expanded mechanically.

Solutions do not have a negative effect on surrounding tissues. Drugs must meet the following requirements:

  • Have a bactericidal effect.
  • Do not damage surrounding tissues upon contact.
  • Do not cause allergies.
  • Do not cause resistance in microorganisms.
  • Have a quick effect.
  • Be active in the presence of organic compounds.
  • Do not have a strong odor.

Today it is almost impossible to select a substance that will meet all of the above requirements. The most popular drug used in dentistry for root canal treatment is sodium hypochloride. It is effective, has broad bactericidal activity, thanks to which it protects the tooth from various microorganisms.

After the treatment, filling is performed. For this purpose, high-quality materials are also selected that will retain their shape and volume in the canal cavity. This property will provide reliable protection against bacterial infection.

Smear layer: to remove or not

When the endodontic instrument comes into contact with the root canal wall, a smear layer is formed. The smear layer consists of the remains of dentinal filings, microorganisms and their toxins. The organic part consists of proteins, microbes, cells, and pulp residues. The inorganic part consists of dentin components.

It has been studied that the smear layer is able to penetrate to varying depths into the lateral tubules, spreading the infection throughout the root canal system. At the same time, it is a physical barrier to microorganisms. It has been scientifically proven that the presence of a smear layer disrupts the adhesion of the sealer in the canal, promotes microleakage, which triggers even greater bacterial growth. Being an obstacle to the penetration of sealer and irrigant into the tubules, it significantly reduces the quality of permanent root canal filling.

The organic component is a breeding ground for bacteria and is easily removed by sodium hypochlorite. The inorganic component of the smear layer is unstable to EDTA and citric acid. The mechanism is associated with demineralization of peritubular dentin and opening of dentinal tubules.

Contraindications to root canal treatment

The procedure has a number of contraindications:

  • Hypertension during a crisis.
  • Diabetes in the stage of decompensation.
  • Diseases of the immune system.
  • Severe osteoporosis.
  • Respiratory infections.

If you are taking medications to thin your blood, you should tell your doctor. In this case, the specialist may prescribe a two-day medication break. If there is a contraindication to the treatment of dental canals, then tooth extraction and prosthetics on an implant can be performed.

Recommendations for recovery

After completing the procedure, you must follow the recommendations:

  • Do not eat food for 2-3 hours. This is because the treatment area will not be sensitive and you may accidentally damage it while eating.
  • For the first few days, do not eat solid foods.
  • Take a course of antibiotics if prescribed by your doctor.
  • Clean your mouth regularly and thoroughly.
  • Place a permanent filling in a timely manner if, after the procedure, the canal was filled with temporary material. If the temporary filling becomes too thin, you should consult a doctor.

In most cases, one week is enough for the rehabilitation period. During this period, the oral cavity is completely restored. In the first 2-3 days, quite intense pain may be observed. During this period, you should take painkillers that are recommended by a specialist. Cephallosporin antibiotics are usually prescribed for a course of 5-7 days.

For high-quality root canal treatment, contact the World of Dentistry clinic. Our undeniable advantage is qualified dentists and the optimal cost of services.

Methods of treatment of dental canals

Not so long ago, arsenic paste was used for endodontic treatment. The dentist opened the dental chamber, put the paste into it and, after the pulp died, removed it from the tooth. Next, the tooth was filled and considered cured. The resorcinol-formalin method was also widely used - a resorcinol-formalin mixture placed in the cavity slowly hardened, stopping the disintegration of the partially removed pulp.

But such technologies have significant disadvantages:

  • Arsenic and formalin saturated with resorcinol are very dangerous, toxic substances that can accumulate in various organs.
  • These substances cannot always kill the nerve completely, which contributes to severe pain when trying to extract the pulp.
  • Infected neurovascular tissues that are not completely removed become a source of repeated inflammation.

These methods were used because there were no sufficiently strong anesthetics that would allow removal of the affected pulp painlessly. Today they are completely irrelevant - modern dentistry treats tooth canals using a completely different technology.

Rating
( 1 rating, average 5 out of 5 )
Did you like the article? Share with friends:
For any suggestions regarding the site: [email protected]